Ordering Code
Symbol
Specification
Orifice size(mm) | Port Thread | Kv(m³/h) | Max. Working Pressure(MPa) | Required Min. Control Pressure(MPa) | PA | Medium Tanperature | Direction |
15 | PTl/2″ | 4.2 | 0-1.6 | 0.39 | 50 | -10~+180℃
| Direction A or B |
20 | PT3/4″ | 8 | 0-1.1 | 0.39 | 50 | ||
25 | PT1″ | 19 | 0-1.1 | 0.42 | 63 | ||
32 | PT1¼” | 27.5 | 0-1.5 | 0.5 | 63 | ||
40 | PT1½” | 42 | 0-1.25 | 0.44 | 63 | ||
50 | PT2″ | 55 | 0-1.0 | 0.4 | 80 | ||
65 | PT2½” | 65 | 0-1.0 | 0.4 | 100 |
Fix and Maintain
1. Clean the pipes carefully from any residue, dribble or welding residue, to avoid any damage to the seal.
2. To be installed as required, preferably with actuator in upright position.
3. Connect the pipes according to the reference points (flow direction) found on the valve body. Only disassemble actuator if required by customer.
4. Before taking the valve apart, depressurize the medium supply and piloted air supply from piping system.
Dimension
Orifice (mm) | Port Thread D | Execution Device Dimension (Φ mm) | A | B | C | 0E | F | G | H | L | S | ||||||
PA | aluminium | PA | aluminium | PA | aluminium | PA | aluminium | PA | aluminium | PA | aluminium | ||||||
15 | PTl/2 | 50 | – | 85 | 173 | – | 12 | 64 | – | 44 | – | 112 | – | 137 | – | 33 | 27 |
20 | PT3/4 | 50 | – | 95 | 178 | – | 12 | 64 | – | 44 | – | 112 | – | 145 | – | 35 | 32 |
25 | PT1″ | 63 | – | 105 | 212 | – | 14 | 80 | – | 52 | – | 120 | – | 173 | – | 40 | 41 |
32 | PT1¼” | 63 | 100 | 118 | 236 | 276 | 16 | 80 | 140 | 52 | 70 | 120 | 138 | 189 | 250 | 35 | 55 |
40 | PT1½” | 63 | 100 | 130 | 230 | 270 | 18 | 80 | 140 | 52 | 70 | 120 | 138 | 189 | 250 | 35 | 55 |
50 | PT2″ | 80 | 125 | 150 | 238 | 300 | 20 | 100 | 170 | 52 | 83 | 120 | 151 | 250 | 260 | 38 | 70 |
65 | PT2½” | 100 | – | 155 | 300 | – | 25 | 125 | – | 62 | – | 130 | – | 265 | – | 48 | 80 |
Note
* Features while select A type flow direction
Increase service life.
Prevent water impact when working medium is liquid.
Product with orifice size at Ø15, Ø20 or Ø25, it is necessary to keep working pressure under 0.3 MPa, otherwise double-acting actuators should be adopted.
Product with orifice size at Ø32 or Ø40, double-acting actuators should be Ø100.
Product with orifice size at Ø50, double-acting actuators should be Ø125.
* Features while select B type flow direction
Sealing property can be improved under B type flow direction while medium is steam or liquid. If the V shape sealing contact with working medium is too long, and it will influence on service life. Apart from that, the anti-water impact does not exit when working medium is liquid.
Firmamız;Hidrolik, Pnömatik ve Otomasyon alanında uzun bir zaman dilimi içerisinde elde ettiği önemli tecrübeleri ve gerçek anlamda uzman kadrosu ile siz değerli müşterilerimizden kaliteli hizmeti, en uygun fiyatlar üzerinden vermeye devam etmektedir.